Description
- Key performance benefit: Continuously monitors resistance for one operator and one work surface, ensuring immediate detection of grounding failures.
- Material & construction: Dual conductor monitoring system designed to measure the resistance of the wrist strap and work surface connections.
- Risk reduction/compliance benefit: Detects both high- and low-resistance faults, reducing the risk of ESD events and grounding failures.
- Protection level: Triggers alarms when operator resistance exceeds 35 megohm or drops to 1.8 megohm. The mat alarm limit is set at 100 megohm.
- Comfort & usability: Provides continuous monitoring without interrupting operator workflow.
- Safety & compliance assurance: No certifications specified.
Recommended For
- Electronics assembly
- Semiconductor fabrication
- Hard drive manufacturing
- ESD-sensitive testing
- Workstation grounding monitoring
- Static control environments
Primary Industries
- Electronics Manufacturing
- Semiconductor
- Industrial Manufacturing
Standards and Certifications
- Not specified
Properties
| Monitoring Capacity | 1 operator, 1 mat |
| Alarm Type | Audible and visual |
| High Resistance Alarm | 35 megohm |
| Low Resistance Alarm | 1.8 megohm |
| Mat Alarm Threshold | 100 megohm |
| Monitoring Type | Dual conductor |