{"title":"Vacuum Controllers by IKA","description":"\u003c!-- split --\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/ika\"\u003eIKA \u003c\/a\u003e\u003c\/li\u003e\n","products":[{"product_id":"ika-works-vc-10-lite-0020111998","title":"IKA Works Vc 10 Lite - 0020111998","description":"\u003cdiv class=\"c-description-area\"\u003e\n   \u003cdiv class=\"container\"\u003e\n      \u003cdiv class=\"c-contentStage-wpr\"\u003e\n         \n         \u003cdiv class=\"row\"\u003e\n            \u003cdiv class=\"col-md-12\"\u003e\n               \u003cdiv class=\"c-product-description-info\"\u003e\n                  \u003ch3\u003eDescription\u003c\/h3\u003e\n                  \u003cdiv class=\"descriptionContent\"\u003e\n                     \u003cdiv class=\"text-overflow\"\u003e\n                        \u003cp\u003eThe IKA VC 10 lite is a speed-controlled universal vacuum controller designed for controlled evacuation of air or gas from laboratory equipment. It supports classic laboratory tasks such as separation, filtration, and drying. The controller is compatible with the VACSTAR digital vacuum pump and requires a cable connection between the devices. It offers both manual and programmable operation, allowing up to ten user-defined pressure\/time sequences. Additional functions include a valve cleaning feature, an integrated ventilation valve, and USB\/RS232 interfaces for PC connection.\u003c\/p\u003e\n\n                        \u003ch4\u003eKey Features\u003c\/h4\u003e\n                        \u003cul\u003e\n                           \u003cli\u003e\n\u003cb\u003eSpeed-Controlled Universal Vacuum Controller:\u003c\/b\u003e Provides precise control of vacuum levels for various laboratory processes.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eCompatible with VACSTAR Digital Pump:\u003c\/b\u003e Ensures seamless integration with the VACSTAR digital vacuum pump.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eManual Mode and Programmable Mode:\u003c\/b\u003e Offers both manual control and programmable operation with up to ten user-defined pressure\/time sequences.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eValve Cleaning Function:\u003c\/b\u003e Enhances service life by ensuring regular valve cleaning.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eIntegrated Ventilation Valve:\u003c\/b\u003e Enables pressure equalization to ensure safe and effective venting.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eUSB and RS232 Interfaces:\u003c\/b\u003e Allows for easy connection to PC software for enhanced control and monitoring.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eDevice-to-Device Communication:\u003c\/b\u003e Facilitates communication between the VC 10 lite and other devices for optimized process control.\u003c\/li\u003e\n                        \u003c\/ul\u003e\n\n                        \u003ch4\u003eApplications\u003c\/h4\u003e\n                        \u003cul\u003e\n                           \u003cli\u003e\n\u003cb\u003eSeparation Processes:\u003c\/b\u003e Ideal for tasks requiring controlled vacuum evacuation during separation processes.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eVacuum Filtration:\u003c\/b\u003e Used in vacuum filtration setups for efficient separation of solids and liquids.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eDrying Applications:\u003c\/b\u003e Supports drying processes by evacuating moisture from materials.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eGeneral Laboratory Equipment Evacuation:\u003c\/b\u003e Suitable for various laboratory tasks requiring precise vacuum control.\u003c\/li\u003e\n                        \u003c\/ul\u003e\n\n                        \u003ch4\u003eBenefits\u003c\/h4\u003e\n                        \u003cul\u003e\n                           \u003cli\u003e\n\u003cb\u003ePrecise Vacuum Control:\u003c\/b\u003e Ensures accurate and reliable vacuum levels for sensitive processes.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eEnhanced Process Automation:\u003c\/b\u003e Programmable features allow for automated, repeatable processes.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eSafe Venting and Pressure Equalization:\u003c\/b\u003e Integrated ventilation valve ensures safe handling of pressure differences.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003ePC Connectivity:\u003c\/b\u003e USB and RS232 interfaces allow integration with PC software for advanced monitoring and control.\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eLong Service Life:\u003c\/b\u003e Valve cleaning function supports extended device longevity.\u003c\/li\u003e\n                        \u003c\/ul\u003e\n\n                        \u003ch4\u003eProduct Specs\u003c\/h4\u003e\n                        \u003cul\u003e\n                           \u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e VC 10 lite\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eInput Pressure Range:\u003c\/b\u003e 1–1050 mbar\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eControl Range:\u003c\/b\u003e 1–1100 mbar\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eResolution:\u003c\/b\u003e 1 mbar\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eConnection Diameter (Suction\/Pressure\/Venting):\u003c\/b\u003e 8 mm\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eDimensions (W × H × D):\u003c\/b\u003e 95 × 150 × 110 mm\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eWeight:\u003c\/b\u003e 1.284 kg\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003ePower Requirements:\u003c\/b\u003e 100–240 V, 50\/60 Hz\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003ePower Input:\u003c\/b\u003e 24 W (2 W standby)\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eInterfaces:\u003c\/b\u003e USB \/ RS232\u003c\/li\u003e\n                           \u003cli\u003e\n\u003cb\u003eCompatibility:\u003c\/b\u003e VACSTAR digital vacuum pump\u003c\/li\u003e\n                        \u003c\/ul\u003e\n\n                        \u003ch4\u003eCategories\u003c\/h4\u003e\n                        \u003cul\u003e\n                           \u003cli\u003eVacuum Controllers\u003c\/li\u003e\n                           \u003cli\u003eIKA Works\u003c\/li\u003e\n                           \u003cli\u003eLaboratory Equipment\u003c\/li\u003e\n                           \u003cli\u003eProcess Control Instruments\u003c\/li\u003e\n                        \u003c\/ul\u003e\n                     \u003c\/div\u003e\n                     \u003ca class=\"btn-overflow\"\u003eSHOW MORE\u003c\/a\u003e\n                  \u003c\/div\u003e\n               \u003c\/div\u003e\n            \u003c\/div\u003e\n         \u003c\/div\u003e\n      \n      \u003c\/div\u003e\n   \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620417765545,"sku":"0020111998","price":1348.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/20111998_1_6fed5c82-a895-49b7-a6b1-825998980f07.jpg?v=1706925060"},{"product_id":"ika-works-vc-10-pro-0020112031","title":"IKA Works Vc 10 Pro - 0020112031","description":"\u003cdiv\u003e\n\u003ch1\u003eVC 10 pro\u003c\/h1\u003e\nValve-controlled, universal vacuum controller for controlled evacuation of air (gas) from laboratory equipment, as well as for classical separation, filtration or drying tasks in the laboratory. The controller is ready-to-use in numerous applications and can be easily installed. \u003cbr\u003e \u003cbr\u003eVC 10 pro can be used with all standard vacuum sources. The use of multiple controllers with one vacuum source is possible. \u003cbr\u003e \u003cbr\u003eFeatures: \u003cul\u003e\n\u003cli\u003e On\/off regulation of multiple vacuum sources\u003c\/li\u003e\n\u003cli\u003e Automatic boiling point detection\u003c\/li\u003e\n\u003cli\u003e Integrated solvent library: Helps to set the correct parameters for example in evaporation processes with rotary evaporators\u003c\/li\u003e\n\u003cli\u003e Graph function\u003c\/li\u003e\n\u003cli\u003e Connection for external temperature sensor: temperature value is shown on display\u003c\/li\u003e\n\u003cli\u003e Valve cleaning function for long service life\u003c\/li\u003e\n\u003cli\u003e Integrated ventilation valve for simple pressure equalization and aeration with inert gas after process completion\u003c\/li\u003e\n\u003cli\u003e VENT short key button allows pressure equalization during a running process\u003c\/li\u003e\n\u003cli\u003e Program function: up to ten user-defined programs can be saved, with up to ten pressure\/time sequences\u003c\/li\u003e\n\u003cli\u003e USB \/ RS232 interfaces for connection with the laboratory software labworldsoft®\u003c\/li\u003e\n\u003cli\u003e Electronic control system for improved process efficiency and higher solvent recovery rate\u003c\/li\u003e\n\u003cli\u003e High energy efficiency thanks to device-to-device communication (vacuum controller to recirculating chiller)\u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003eFor additional safety for users and environment, the use of the VSE 1 vacuum safety emission condenser is recommended, which prevents solvents from being released into the room air. The VSE 1 is available as an accessory. \u003cbr\u003e\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter suction side\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter pressure side\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter venting side\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput pressure\u003c\/td\u003e\n\u003ctd\u003e1 - 1050 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoiling point detection\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolvent library\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo-point control\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog speed vacuum control\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure unit \/ scale\u003c\/td\u003e\n\u003ctd\u003embar, hPa, mmHg, Torr \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum sensor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum sensor type\u003c\/td\u003e\n\u003ctd\u003eceramic Al2O3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure max. for pressure sensor\u003c\/td\u003e\n\u003ctd\u003e1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range (absolute)\u003c\/td\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl range\u003c\/td\u003e\n\u003ctd\u003e1 - 1100 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution pressure\u003c\/td\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement uncertainty\u003c\/td\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium temperature (gas)\u003c\/td\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum valve\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting valve\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection for ext. temperature sensor\u003c\/td\u003e\n\u003ctd\u003ePT1000 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature unit\u003c\/td\u003e\n\u003ctd\u003e°C \/ °F \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measuring range\u003c\/td\u003e\n\u003ctd\u003e-10 - 200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement resolution \u003c\/td\u003e\n\u003ctd\u003e1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy of temperature measurement\u003c\/td\u003e\n\u003ctd\u003e±1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime setting min. \u003c\/td\u003e\n\u003ctd\u003e1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime setting max.\u003c\/td\u003e\n\u003ctd\u003e6000 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum speed control interface\u003c\/td\u003e\n\u003ctd\u003eVACSTAR \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial in contact with medium\u003c\/td\u003e\n\u003ctd\u003eAl2O3, PTFE, FPM, PPS \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003ePBT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening\u003c\/td\u003e\n\u003ctd\u003estand \/ clamp \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening diameter\u003c\/td\u003e\n\u003ctd\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode automatic\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode manual\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode pump %\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode program\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph function\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChiller control\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum leakage test\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e95 x 150 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input standby\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V=\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e1000 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620417798313,"sku":"0020112031","price":2032.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/20112031_1_9dc27cbe-4c4c-47a9-9369-66420b96370e.jpg?v=1706925062"},{"product_id":"ika-works-mvp-10-basic-vacuum-pump-0003980001","title":"IKA Works Mvp 10 Basic Vacuum Pump - 0003980001","description":"\u003cdiv\u003e\n\u003ch1\u003eMVP 10 basic vacuum pump\u003c\/h1\u003e\nFor dry, oil-free applications \u003cul\u003e\n\u003cli\u003e Slimline, compact design and long service life\u003c\/li\u003e\n\u003cli\u003e Straightforward servicing and simple maintenance\u003c\/li\u003e\n\u003cli\u003e Diaphragm pump that is highly resistant to chemicals as all parts that come into contact with gas are made of PTFE or PTFE compounds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cb\u003eScope of delivery\u003c\/b\u003e\u003cul style=\"padding-top:0px\"\u003e\n\u003cli\u003eMVP 10 basic vacuum pump\u003c\/li\u003e\n\u003cli\u003eVacuum hose\u003c\/li\u003e\n\u003cli\u003eSilencer\u003c\/li\u003e\n\u003cli\u003eY hose connector 8 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump rate max. (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e1.7 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump rate max. (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e28.3 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal pressure without gas ballast\u003c\/td\u003e\n\u003ctd\u003e7 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal pressure with gas ballast\u003c\/td\u003e\n\u003ctd\u003e15 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction levels\u003c\/td\u003e\n\u003ctd\u003e2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003ctd\u003e2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter suction side\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter pressure side\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas ballast valve\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput pressure\u003c\/td\u003e\n\u003ctd\u003e7 - 1050 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed (50Hz)\u003c\/td\u003e\n\u003ctd\u003e1380 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed (60Hz)\u003c\/td\u003e\n\u003ctd\u003e1680 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise at low. pressure\u003c\/td\u003e\n\u003ctd\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e245 x 155 x 320 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e10 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 54 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e180 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620417831081,"sku":"3980001","price":2162.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/3980000_1_00888cc2-e7a9-4010-b9a3-7d406132c8df.jpg?v=1706925065"},{"product_id":"ika-works-vacstar-digital-0020016237","title":"IKA Works Vacstar Digital - 0020016237","description":"\u003cdiv\u003e\n\u003ch1\u003eVACSTAR digital\u003c\/h1\u003e\nThe four-chamber membrane vacuum pump convinces with its high suction capacity, low space requirement and high serviceability. The setting of the parameters is carried out through a rotary-push button over a digital display showing current rpm. \u003cbr\u003eAutomated processes are controlled with the vacuum controller VC 10, which is available as an accessory. An analogue cable which is required for connecting pump and controller is included in the delivery of the pump. Additionally it is recommended to use the VSE 1 vacuum safety emmission. It prevents that solvents are released into ambient air. \u003cbr\u003eThe Vacstar digital is used for dry and oil-free applications in the laboratory. The membranes of the pump are particularly chemical resistant. \u003cbr\u003e \u003cbr\u003e\n\u003cb\u003eScope of delivery\u003c\/b\u003e\u003cul style=\"padding-top:0px\"\u003e\n\u003cli\u003eVacuum hose (1 m)\u003c\/li\u003e\n\u003cli\u003eSilencer\u003c\/li\u003e\n\u003cli\u003eUSB A-B Cable\u003c\/li\u003e\n\u003cli\u003econnecting cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump rate max. (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e1.32 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump rate max. (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e22 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal pressure without gas ballast\u003c\/td\u003e\n\u003ctd\u003e2 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction levels\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter suction side\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter pressure side\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput pressure\u003c\/td\u003e\n\u003ctd\u003e2 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo-point control\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog speed vacuum control\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed adjustment\u003c\/td\u003e\n\u003ctd\u003eTurning knob \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed range\u003c\/td\u003e\n\u003ctd\u003e285 - 1200 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLED \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise at low. pressure\u003c\/td\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial in contact with medium\u003c\/td\u003e\n\u003ctd\u003eAl2O3; PTFE; FFPM; PPS; NBR \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003ealu-cast coating \/ thermoplastic polymer \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e150 x 375 x 370 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80% (up to 31°C), decreasing linearly to max. 50 (@40°C) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e130 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input standby\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620417896617,"sku":"0020016237","price":3068.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/20016236_1_1d2fc416-2f8c-423c-99ba-8c57fe07db1b.jpg?v=1706925067"},{"product_id":"ika-works-vacstar-control-0020109376","title":"IKA Works Vacstar Control - 0020109376","description":"\u003cdiv\u003e\n\u003ch1\u003eVACSTAR control\u003c\/h1\u003e\nSeparation, filtration, removal: The VACSTAR dry 4-chamber membrane vacuum pump is powerful, resistant to chemicals and low-maintenance. VACSTAR control is the ideal system with its integrated vacuum controller and removable display. The controller offers a suitable mode for the desired process: from automatic to manual operation, right through to pumping or an evacuation and cleaning function. \u003cbr\u003e \u003cbr\u003eHigh-performance suction \u003cbr\u003eVACSTAR has an excellent suction performance, with its 22 l\/min at a minimum of 2 mbar. \u003cbr\u003e \u003cbr\u003eIntegrated vacuum controller with removable controller (WiCo) \u003cbr\u003eDepending on the application, you can easily select your operating mode either by using the intuitive operator menu or by remote control. \u003cbr\u003e \u003cbr\u003eFor additional safety for users and environment, we recommend using the VSE 1 vacuum safety emission condenser, which prevents solvents from being released into the room air. The VSE 1 is available as accessory. \u003cbr\u003e\n\u003cb\u003eScope of delivery\u003c\/b\u003e\u003cul style=\"padding-top:0px\"\u003e\n\u003cli\u003eWiCo VACSTAR control\u003c\/li\u003e\n\u003cli\u003eVacuum hose (1 m)\u003c\/li\u003e\n\u003cli\u003eWH11\u003c\/li\u003e\n\u003cli\u003eOS 1.0 WiCo power supply unit \u003c\/li\u003e\n\u003cli\u003eUSB Cable - USB A to Micro-B, 2 m\u003c\/li\u003e\n\u003cli\u003eUSB A-B Cable\u003c\/li\u003e\n\u003cli\u003eScrew driver \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump rate max. (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e1.32 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump rate max. (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e22 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal pressure without gas ballast\u003c\/td\u003e\n\u003ctd\u003e2 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction levels\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter suction side\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection diameter pressure side\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput pressure\u003c\/td\u003e\n\u003ctd\u003e2 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoiling point detection\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolvent library\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog speed vacuum control\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed adjustment\u003c\/td\u003e\n\u003ctd\u003eTurning knob \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed range\u003c\/td\u003e\n\u003ctd\u003e285 - 1200 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure unit \/ scale\u003c\/td\u003e\n\u003ctd\u003embar, hPa, mmHg, Torr \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum sensor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum sensor type\u003c\/td\u003e\n\u003ctd\u003eceramic Al2O3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure max. for pressure sensor\u003c\/td\u003e\n\u003ctd\u003e1.2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range (absolute)\u003c\/td\u003e\n\u003ctd\u003e1 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl range\u003c\/td\u003e\n\u003ctd\u003e1 - 1030 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution pressure\u003c\/td\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement uncertainty\u003c\/td\u003e\n\u003ctd\u003e1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVenting valve\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondensate trap\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission condenser\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise at low. pressure\u003c\/td\u003e\n\u003ctd\u003e54 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial in contact with medium\u003c\/td\u003e\n\u003ctd\u003eAl2O3, PTFE, FPM, PPS \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003ealu-cast coating \/ thermoplastic polymer \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode automatic\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode manual\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode pump %\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode program\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e270 x 435 x 500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80% (up to 31°C), decreasing linearly to max. 50 (@40°C) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e140 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input standby\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620417962153,"sku":"0020109376","price":5460.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/20109375_1_73a35891-64f0-4e81-930f-98f5a49d37fb.jpg?v=1706925070"}],"url":"https:\/\/labproinc.myshopify.com\/collections\/wsc-vacuum-controllers-by-ika.oembed","provider":"Lab Pro Inc","version":"1.0","type":"link"}