{"product_id":"ika-works-c-200-h-auto-0010002388","title":"IKA Works C 200 H Auto - 0010002388","description":"\u003cdiv\u003e\n\u003ch1\u003eC 200 h auto\u003c\/h1\u003e\nThe C 200 h auto package allows operating the C 200 with a completely automated water cycle. This results in ease of handling and saves valuable time especially for laboratories with a low number of analyses. The water circulates in a closed loop and is kept at a constant temperature by using a recirculating chiller. This leads to shorter preparation time for each experiment and even better reproducible results. \u003cbr\u003e \u003cbr\u003eThe scope of delivery includes: \u003cbr\u003eC 200 calorimeter measuring cell \u003cbr\u003eC 5012 halogen resistant, catalytic activated decomposition vessel \u003cbr\u003eC 200.2 conversion kit for C 5012 \u003cbr\u003eC 248 oxygen filling station \u003cbr\u003eRC 2 basic circulating chiller \u003cbr\u003eC 200.RC hose set \u003cbr\u003eConsumables for calibration and installation \u003cbr\u003e \u003cbr\u003eThe semi-automated and conforming-to-standards combustion calorimeter determines the gross calorific value of liquid and solid samples. So far it has mainly been used for teaching and training purposes at technical schools and universities. Due to the automated water handling it is now also suitable for industrial laboratories with low number of analyses. \u003cbr\u003e \u003cbr\u003eThe catalytic activated, halogen resistant decomposition vessel C 5012 is specifically designed for the combustion of samples that contain halogens and sulfur ( \u0026gt; 3 % ). The material of the decomposition vessel (Hastelloy) prevents corrosion caused by samples with high chlorine content. The catalytic activated inner-surface leads to higher recovery rates in case analysis of halogens and\/or sulfur is required after the combustion. \u003cbr\u003e \u003cbr\u003eFour different operation modes enable the user to control the measuring times according to individual requirements: \u003cbr\u003eIsoperibol: approx: 17 min. \u003cbr\u003eDynamic: approx. 8 min \u003cbr\u003eManual: approx. 17 min (depends on the operator) \u003cbr\u003eTime controlled: 14 min \u003cbr\u003e \u003cbr\u003eMeasurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711. \u003cbr\u003e \u003cbr\u003eThe software C 6040 CalWin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. CalWin is sold separately. \u003cbr\u003e\u003cbr\u003e\n\u003cb\u003eScope of delivery\u003c\/b\u003e\u003cul style=\"padding-top:0px\"\u003e\n\u003cli\u003eC 200\u003c\/li\u003e\n\u003cli\u003eC 5012 Decomposition vessel, halogen resistant\u003c\/li\u003e\n\u003cli\u003eC 200.2 Conversion kit for C 5012\u003c\/li\u003e\n\u003cli\u003eC 200.RC Set of hoses\u003c\/li\u003e\n\u003cli\u003eRC 2 basic\u003c\/li\u003e\n\u003cli\u003eC 248 Oxygen filling station\u003c\/li\u003e\n\u003cli\u003eIgnation adapter\u003c\/li\u003e\n\u003cli\u003eWater emptying hose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range max.\u003c\/td\u003e\n\u003ctd\u003e40000 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring mode dynamic 25°C\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring mode isoperibol 25°C\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time dynamic approx.\u003c\/td\u003e\n\u003ctd\u003e8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time isoperibol approx.\u003c\/td\u003e\n\u003ctd\u003e17 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReproducibility dynamic (1g benzoic acid NBS39i)\u003c\/td\u003e\n\u003ctd\u003e0.1 %RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReproducibility isoperibol (1g benzoic acid NBS39i)\u003c\/td\u003e\n\u003ctd\u003e0.1 %RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature max. \u003c\/td\u003e\n\u003ctd\u003e25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement resolution \u003c\/td\u003e\n\u003ctd\u003e0.0001 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling medium permissible operating pressure\u003c\/td\u003e\n\u003ctd\u003e2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling medium\u003c\/td\u003e\n\u003ctd\u003etap water \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of cooling\u003c\/td\u003e\n\u003ctd\u003eflow \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChiller\u003c\/td\u003e\n\u003ctd\u003eRC 2 basic \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRec. flow rate at 18°C\u003c\/td\u003e\n\u003ctd\u003e60 l\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen operating pressure max. \u003c\/td\u003e\n\u003ctd\u003e40 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface printer\u003c\/td\u003e\n\u003ctd\u003eCentronix \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface PC\u003c\/td\u003e\n\u003ctd\u003eRS232 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDecomposition vessel C 5012\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN 51900\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN EN ISO 1716\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN EN ISO 18125\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN EN 15400\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN CEN TS 14918\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN CEN\/TS 16023\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN SPEC 19524\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ASTM D240\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ASTM D4809\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ASTM D5468\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ASTM D5865\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ISO 1928\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to GOST Certified\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e400 x 400 x 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e20 - 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620401250473,"sku":"0010002388","price":34512.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/10002379_1.jpg?v=1706924331","url":"https:\/\/labproinc.myshopify.com\/products\/ika-works-c-200-h-auto-0010002388","provider":"Lab Pro Inc","version":"1.0","type":"link"}