{"product_id":"ika-works-c-6000-isoperibol-package-2-10-0010004537","title":"IKA Works C 6000 Isoperibol Package 2\/10 - 0010004537","description":"\u003cdiv\u003e\n\u003ch1\u003eC 6000 isoperibol Package 2\/10\u003c\/h1\u003e\nThe C 6000 isoperibol oxygen bomb calorimeter combines modern technology, variability and automation in one instrument. It operates according to all bomb calorimeter standards, such as e.g. the DIN, ISO, ASTM, GOST and GB. The operator can choose between three different starting temperatures 22 °C, 25 °C, 30 °C in each measuring mode. Due to the new design of the decomposition vessel the measurement time could be reduced. Due to the variety of different interfaces for PC, printer (Ethernet, serial and USB), balance and USB Stick this unit is easily adaptable to the customer’s specific application needs. Further adaption to data management and LIMS is possible with our calorimeter software C 6040 Calwin (Accessory). \u003cbr\u003e \u003cbr\u003eMeasuring modes: \u003cul\u003e\n\u003cli\u003e isoperibol\u003c\/li\u003e\n\u003cli\u003e dynamic\u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003eFeatures: \u003cul\u003e\n\u003cli\u003e Automatic ignition and ignition energy determination\u003c\/li\u003e\n\u003cli\u003e Automatic water filling and draining\u003c\/li\u003e\n\u003cli\u003e Automatic oxygen filling, venting and flushing\u003c\/li\u003e\n\u003cli\u003e RFID technology for automatic decomposition vessel identification\u003c\/li\u003e\n\u003cli\u003e New design of the decomposition vessel allowing easier and faster sample preparation\u003c\/li\u003e\n\u003cli\u003e Easy and convenient capacitive touch screen operation\u003c\/li\u003e\n\u003cli\u003e Control chart view and correction calculation of globally used standards\u003c\/li\u003e\n\u003cli\u003e Ethernet interface to connect a network printer\u003c\/li\u003e\n\u003cli\u003e USB interface allowing easy data management and software updates\u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003eThe C 6000 isoperibol Package 2\/10 consists of: \u003cul\u003e\n\u003cli\u003e C 6000 isoperibol \u003c\/li\u003e\n\u003cli\u003e C 6010 decomposition vessel, standard \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cb\u003eScope of delivery\u003c\/b\u003e\u003cul style=\"padding-top:0px\"\u003e\n\u003cli\u003eC 6000 isoperibol\u003c\/li\u003e\n\u003cli\u003eC 6010 Decomposition vessel, standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range max.\u003c\/td\u003e\n\u003ctd\u003e40000 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring mode dynamic 22°C\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring mode isoperibol 22°C\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring mode dynamic 25°C\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring mode isoperibol 25°C\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring mode dynamic 30°C\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring mode isoperibol 30°C\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurements\/h dynamic\u003c\/td\u003e\n\u003ctd\u003e6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurements\/h isoperibol\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReproducibility dynamic (1g benzoic acid NBS39i)\u003c\/td\u003e\n\u003ctd\u003e0.15 %RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReproducibility isoperibol (1g benzoic acid NBS39i)\u003c\/td\u003e\n\u003ctd\u003e0.05 %RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature\u003c\/td\u003e\n\u003ctd\u003e22 - 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement resolution \u003c\/td\u003e\n\u003ctd\u003e0.0001 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling medium temperature\u003c\/td\u003e\n\u003ctd\u003e12 - 27 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling medium permissible operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling medium\u003c\/td\u003e\n\u003ctd\u003etap water \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of cooling\u003c\/td\u003e\n\u003ctd\u003eflow \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChiller\u003c\/td\u003e\n\u003ctd\u003eRC 2 basic \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow rate\u003c\/td\u003e\n\u003ctd\u003e60 - 70 l\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRec. flow rate at 18°C\u003c\/td\u003e\n\u003ctd\u003e60 l\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen operating pressure max. \u003c\/td\u003e\n\u003ctd\u003e40 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface scale\u003c\/td\u003e\n\u003ctd\u003eRS232 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface printer\u003c\/td\u003e\n\u003ctd\u003eUSB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface PC\u003c\/td\u003e\n\u003ctd\u003eRS232 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface test rack\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface ext. keyboard\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen filling\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegasification\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDecomposition detection\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDecomposition vessel C 6010\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis according to DIN 51900\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis according to ASTM D240\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis according to ASTM D4809\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis according to ASTM D5865\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis according to ISO 1928\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis according to GB T213\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN 51900\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN EN ISO 1716\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN EN ISO 9831\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN EN ISO 18125\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN EN 15170\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN EN 15400\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN CEN TS 14918\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN CEN\/TS 16023\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to DIN SPEC 19524\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ASTM D240\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ASTM D4809\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ASTM D5468\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ASTM D5865\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to ISO 1928\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to GB T213\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorks according to GOST Certified\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e500 x 425 x 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e40.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e20 - 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e1700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620400726185,"sku":"0010004537","price":37181.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/10004524_1_41826736-96f2-43cc-b83b-2da7a45e7503.jpg?v=1706924320","url":"https:\/\/labproinc.myshopify.com\/products\/ika-works-c-6000-isoperibol-package-2-10-0010004537","provider":"Lab Pro Inc","version":"1.0","type":"link"}