{"product_id":"ika-works-habitat-photo-ferment-cct-0010007606","title":"IKA Works Habitat Photo Ferment Cct - 0010007606","description":"\u003cdiv\u003e\n\u003ch1\u003eHABITAT photo ferment cct\u003c\/h1\u003e\n\u003cbr\u003e* may be combined with double-walled vessel packages \u003cbr\u003e \u003cbr\u003eThe HABITAT photo ferment cct control unit package of the HABITAT research bioreactor is used to monitor and control the bioprocess. With the help of the LED panels included in the scope of delivery, the system can be used as a photobioreactor, for example for algae cultivation. The adjustment of the light intensity enables the simulation of the day-night rhythm. Furthermore, the package includes the control unit with all connection options for the gas supply, liquid addition, sensors and temperature control as well as a tablet for simple and clear operation of the bioreactor. In addition to the HABITAT cell package, you have the option of connecting CO2, conductivity and turbidity sensors. \u003cbr\u003e \u003cbr\u003eControl and monitoring \u003cbr\u003eThe bioprocess and all associated test parameters can be easily controlled and monitored via the tablet attached to the control unit and with the help of the intuitive and easy-to-use software. Depending on the type of cultivation, you can choose between the operating modes batch, fed-batch and perfusion\/continuous. The new Chaotic Mixing function ensures faster and more effective mixing when required. The 10.4-inch tablet allows direct access to all actuators directly on the main screen. A clear calibration management, a diagram overview and the complete documentation of the process round off the operation. A software version that meets FDA CFR Part 11 requirements is available as an option. \u003cbr\u003e \u003cbr\u003eGas supply \u003cbr\u003eBuilt in mass flow controllers for 4 separate gas lines (for N2, O2, air and CO2) ensure precise, individually adjustable gassing, ideally tailored to the needs of your cells. Flow rates of 0.1-20 l\/min can be achieved. \u003cbr\u003e \u003cbr\u003eLiquid supply \u003cbr\u003e4 integrated Watson Marlow pumps, adjustable in direction and speed, give you the variability to pump in and pump out different liquids (like acid, base, anti-foam agent, feeding solutions). \u003cbr\u003e \u003cbr\u003eSensors \u003cbr\u003eHABITAT cell enables the measurement of the following parameters by means of sensors: \u003cbr\u003e• pH \u003cbr\u003e• DO (dissolved oxygen) \u003cbr\u003e• temperature \u003cbr\u003e• filling level \u003cbr\u003e• foam \u003cbr\u003e \u003cbr\u003eTemperature control \u003cbr\u003eThe constant and precise temperature control during the cultivation is guaranteed by the heating sleeve, which is adapted to the respective vessel size. (Heating sleeve is included with the HABITAT cell vessel package). \u003cbr\u003e \u003cbr\u003eAll features at a glance \u003cbr\u003e\u0026gt; compact, space-saving design, dimensions: 223 x 402 x 450 mm (WxDxH) \u003cbr\u003e\u0026gt; large tablet for clear operation (10,4 inch) \u003cbr\u003e\u0026gt; intuitive, easy-to-use software with a lot of functionalities. \u003cbr\u003e\u0026gt; 4 integrated fast-load pumps (Watson Marlow) \u003cbr\u003e\u0026gt; connectivity: USB, PC, RS232, ethernet, external signal input, external pump, single-use unit, thermostat \u003cbr\u003e\u0026gt; data storage \u003cbr\u003e\u0026gt; gas supply with 4 built-in mass flow controllers: e.g. for O2, Luft, N2, CO2 \u003cbr\u003e\u0026gt; Status LED display: direct error display by indicator light \u003cbr\u003e \u003cbr\u003eNote: Only a control tower package and the separately available vessel package make up a functional unit. \u003cbr\u003e\n\u003cb\u003eScope of delivery\u003c\/b\u003e\u003cul style=\"padding-top:0px\"\u003e\n\u003cli\u003eHABITAT photo ferment cct S099\u003c\/li\u003e\n\u003cli\u003eTablet with software for bioreactor\u003c\/li\u003e\n\u003cli\u003eHA.pl. Peltier cooling element\u003c\/li\u003e\n\u003cli\u003eLED panel (2pcs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eFermenter \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating mode\u003c\/td\u003e\n\u003ctd\u003etimer, continuous and program operation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eTablet PC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd\u003etouch screen \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData memory size\u003c\/td\u003e\n\u003ctd\u003e32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto restart after power failure\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle use reactor interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostat interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExt. pump interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter heater\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED light panel\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirring motor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration guide tepmerature\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration guide pH\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration guide pO2\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH - temperature compensation\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode hose filling\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer control mode\u003c\/td\u003e\n\u003ctd\u003eoff, manual, profile, Cascade-pO2 control, chaotic \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed range\u003c\/td\u003e\n\u003ctd\u003e1 - 2200 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed deviation \u0026gt;= 100 rpm\u003c\/td\u003e\n\u003ctd\u003e±2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed deviation \u0026lt;= 100 rpm\u003c\/td\u003e\n\u003ctd\u003e±5 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed display\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReversible direction of rotation \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer display\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime setting range\u003c\/td\u003e\n\u003ctd\u003e1 - 120 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating blanket\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat output\u003c\/td\u003e\n\u003ctd\u003e250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat control\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control\u003c\/td\u003e\n\u003ctd\u003ePID \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature\u003c\/td\u003e\n\u003ctd\u003e5 - 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection for ext. temperature sensor\u003c\/td\u003e\n\u003ctd\u003ePT1000 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature display\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measuring range\u003c\/td\u003e\n\u003ctd\u003e0 - 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement resolution \u003c\/td\u003e\n\u003ctd\u003e0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control accuracy \u003c\/td\u003e\n\u003ctd\u003e±0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature limit min.\u003c\/td\u003e\n\u003ctd\u003e0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature limit max.\u003c\/td\u003e\n\u003ctd\u003e110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH measurement\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH control mode\u003c\/td\u003e\n\u003ctd\u003eoff, auto, profile \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH value display\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH measuring range\u003c\/td\u003e\n\u003ctd\u003e0 - 14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH measurement resolution \u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy of pH measurement\u003c\/td\u003e\n\u003ctd\u003e0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConncetion for pO2 sensor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epO2 control mode\u003c\/td\u003e\n\u003ctd\u003eoff, manual, auto, profile \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range pO2 min.\u003c\/td\u003e\n\u003ctd\u003e0 %sat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range pO2 max.\u003c\/td\u003e\n\u003ctd\u003e200 %sat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution pO2 measurement\u003c\/td\u003e\n\u003ctd\u003e0.01 %sat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy of pO2 measurement\u003c\/td\u003e\n\u003ctd\u003e0.3 %sat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConncetion for turbidity sensor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity control mode\u003c\/td\u003e\n\u003ctd\u003eMonitoring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConncetion for conductivity sensor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity control mode\u003c\/td\u003e\n\u003ctd\u003eMonitoring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConncetion for CO2 sensor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2 control mode\u003c\/td\u003e\n\u003ctd\u003eMonitoring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas in connection Air\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas out connection Air \u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas in connection O2\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas out connection O2\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas in connection N2\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas out connection N2\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas in connection CO2\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas out connection CO2\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAeration mode\u003c\/td\u003e\n\u003ctd\u003econtinuous \u0026amp; automatic \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay flowrate\u003c\/td\u003e\n\u003ctd\u003el\/min, cc\/min \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput pressure\u003c\/td\u003e\n\u003ctd\u003e200 - 3000 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure out min.\u003c\/td\u003e\n\u003ctd\u003e200 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure out max.\u003c\/td\u003e\n\u003ctd\u003e1000 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowrate Air min.\u003c\/td\u003e\n\u003ctd\u003e0 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowrate Air max.\u003c\/td\u003e\n\u003ctd\u003e20000 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowrate O2 min.\u003c\/td\u003e\n\u003ctd\u003e0 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowrate O2 max.\u003c\/td\u003e\n\u003ctd\u003e20000 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowrate N2 min.\u003c\/td\u003e\n\u003ctd\u003e0 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowrate N2 max.\u003c\/td\u003e\n\u003ctd\u003e20000 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowrate CO2 min.\u003c\/td\u003e\n\u003ctd\u003e0 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowrate CO2 min.\u003c\/td\u003e\n\u003ctd\u003e20000 cc\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring and control accuracy of the gas control units\u003c\/td\u003e\n\u003ctd\u003e2 % fsr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeristaltic pump\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumbers of pump heads\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump head function\u003c\/td\u003e\n\u003ctd\u003eAcid, Base, AntiFoam, Level \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump head\u003c\/td\u003e\n\u003ctd\u003eWatson Marlow 114DV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of pump tubes\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of pump rollers\u003c\/td\u003e\n\u003ctd\u003e4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow rate min.\u003c\/td\u003e\n\u003ctd\u003e1.0 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow rate max.\u003c\/td\u003e\n\u003ctd\u003e270 ml\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Speed min.\u003c\/td\u003e\n\u003ctd\u003e100 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Speed max.\u003c\/td\u003e\n\u003ctd\u003e400 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump reversible direction of rotation\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump speed display\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner tube diameter min. \u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner tube diameter max.\u003c\/td\u003e\n\u003ctd\u003e4.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube outer diamter min.\u003c\/td\u003e\n\u003ctd\u003e4.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube outer diamter max.\u003c\/td\u003e\n\u003ctd\u003e8.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube material \u003c\/td\u003e\n\u003ctd\u003eSilicone \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube hardness\u003c\/td\u003e\n\u003ctd\u003e50 - 60 Shore A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e224 x 624 x 405 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80% (up to 31°C), decreasing linearly to max. 50 (@40°C) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 20 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiFi Interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input max.\u003c\/td\u003e\n\u003ctd\u003e1100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input standby\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e2x T5.0A 250V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620399317161,"sku":"0010007606","price":14611.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/10007553_1_8fd63393-f6ba-4479-9c6b-06f12039dc23.jpg?v=1706924269","url":"https:\/\/labproinc.myshopify.com\/products\/ika-works-habitat-photo-ferment-cct-0010007606","provider":"Lab Pro Inc","version":"1.0","type":"link"}