{"product_id":"ika-works-hbc-5-control-0004127001","title":"IKA Works Hbc 5 Control - 0004127001","description":"\u003cdiv\u003e\n\u003ch1\u003eHBC 5 control\u003c\/h1\u003e\nThe HBC 5 control heated bath circulator heats up to a max. temperature of 250 °C. It has a high quality stainless steel bath with a volume of 5 – 7 liters. The TFT display is in color and illustrates all relevant parameters. With just one key, the internal temperature regulation can be switched to external temperature regulation. The large surface of the radiator allows for an optimum heat exchange and a gentle heating process of the medium. Push and turn buttons allow for intuitive menu navigation. The menu comes in different languages. The bath has a front drain valve for safe emptying. In order to drain the bath, a hose is connected so there is no direct contact with the tempering fluid. With the unique WiCo Wireless Controller, the unit can be operated from a distance of up to 10 meters\/3 ft. \u003cbr\u003e \u003cul\u003e\n\u003cli\u003e Temperature range: 20 – 250 °C\u003c\/li\u003e\n\u003cli\u003e Temperature accuracy: ± 0.01 K\u003c\/li\u003e\n\u003cli\u003e Wireless Controller (WiCo) enables safe operation, e.g. outside of a closed fume hood\u003c\/li\u003e\n\u003cli\u003e Large easy to read TFT display for temperature, pump speed, filling level and safety temperature.\u003c\/li\u003e\n\u003cli\u003e Integrated cooling coil\u003c\/li\u003e\n\u003cli\u003e Powerful, speed controlled pressure\/suction pump\u003c\/li\u003e\n\u003cli\u003e Adjustable safety circuit\u003c\/li\u003e\n\u003cli\u003e Safety classification III (FL) according to DIN 12876 \u003c\/li\u003e\n\u003cli\u003e Timer function: 0 – 99 h 59 min\u003c\/li\u003e\n\u003cli\u003e Visual and acoustic safety warning\u003c\/li\u003e\n\u003cli\u003e Connection of a magnetic valve possible\u003c\/li\u003e\n\u003cli\u003e USB \/ RS 232 interface for PC control and documentation using labworldsoft®, as well as updating the device software through our website\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cb\u003eScope of delivery\u003c\/b\u003e\u003cul style=\"padding-top:0px\"\u003e\n\u003cli\u003eHBC 5 control\u003c\/li\u003e\n\u003cli\u003eHose olive NW 12 (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eCC1\u003c\/li\u003e\n\u003cli\u003eScrewdriver (use for safety circuit) \u003c\/li\u003e\n\u003cli\u003eOS 1.0 power supply (for WiCo) \u003c\/li\u003e\n\u003cli\u003eUSB Cable - USB A to Micro-B, 2 m\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 cable Micro A – Micro B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eCirculation thermostat \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass designation acc. DIN 12876\u003c\/td\u003e\n\u003ctd\u003eIII \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentification according to DIN 12876\u003c\/td\u003e\n\u003ctd\u003eFL \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat output\u003c\/td\u003e\n\u003ctd\u003e1250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature\u003c\/td\u003e\n\u003ctd\u003eroom temp. +10K @1000rpm - 250 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature min. (with external cooling)\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature display\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control\u003c\/td\u003e\n\u003ctd\u003ePID \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature sensor\u003c\/td\u003e\n\u003ctd\u003ePT 100 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety temperature sensor\u003c\/td\u003e\n\u003ctd\u003ePT1000 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature display\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety temperature display\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature stability DIN 12876\u003c\/td\u003e\n\u003ctd\u003e±0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection for ext. temperature sensor\u003c\/td\u003e\n\u003ctd\u003ePT 100 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay for operation with ext. sensor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet temperature resolution\u003c\/td\u003e\n\u003ctd\u003e±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning function optical \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning function acoustic \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning function excess temperature \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable safety circuit\u003c\/td\u003e\n\u003ctd\u003e0 - 260 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-level protection\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-level protection \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilling volume\u003c\/td\u003e\n\u003ctd\u003e5 - 7 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump type\u003c\/td\u003e\n\u003ctd\u003ePressure- \/ suction pump \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump capacity adjustable \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump pressure max. (0 liters discharge flow)\u003c\/td\u003e\n\u003ctd\u003e0.61 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure pump (suction side) (0 liter flow)\u003c\/td\u003e\n\u003ctd\u003e0.45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow rate max. (0 bar back pressure)\u003c\/td\u003e\n\u003ctd\u003e31 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump connection\u003c\/td\u003e\n\u003ctd\u003eM16x1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling coil connection\u003c\/td\u003e\n\u003ctd\u003eNW 8 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBath depth min.\u003c\/td\u003e\n\u003ctd\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth bath opening\u003c\/td\u003e\n\u003ctd\u003e172 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth bath opening\u003c\/td\u003e\n\u003ctd\u003e82 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration option\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical data complies with the standard\u003c\/td\u003e\n\u003ctd\u003eDIN 12876 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ON time\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm output (potential-free contact) max. \u003c\/td\u003e\n\u003ctd\u003e30 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm output (potential-free contact) max. \u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolenoid valve output\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolenoid valve output max.\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby input\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e275 x 406 x 500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e17.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e5 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 21 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100 - 115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e1400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620416389289,"sku":"0004127001","price":5986.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/4127000_1_76fe328c-0b2d-400b-bf3c-632ba3551328.jpg?v=1706924984","url":"https:\/\/labproinc.myshopify.com\/products\/ika-works-hbc-5-control-0004127001","provider":"Lab Pro Inc","version":"1.0","type":"link"}