{"product_id":"ika-works-rc-5-control-0020008504","title":"IKA Works Rc 5 Control - 0020008504","description":"\u003cdiv\u003e\n\u003ch1\u003eRC 5 control\u003c\/h1\u003e\nPowerful recirculating chiller, designed for external cooling applications up to -30°C. \u003cbr\u003eThe energy-efficient chiller is operated with an eco-friendly refrigerant and reaches a high power density. This results in a comparatively small working space in the lab. The speed-controlled PEEK pump allows an indirect, continuous adjustment of the maximum pressure and flow rate. Due to the PT100 temperature sensor, which is part of the delivery and its excellent temperature stability of about ± 0,1 K, the RC 5 can handle even sophisticated applications. \u003cbr\u003eLaboratory staff operates the RC 5 control safely and conveniently from everywhere in the lab by using the Wireless Controller (WiCo). Processes can be automated and simplified through 10 freely programmable temperature ramps with 10 steps each. \u003cbr\u003eIts isolated, high-quality 7l bath has an integrated hopper and drain valve, ensuring safe and clean handling of the thermofluid. A hose can be connected to empty the bath in order to avoid direct contact with the thermofluid. \u003cbr\u003eThe easy-to-open front flap allows an easy cleaning of the cooling unit’s air filter. \u003cbr\u003e \u003cbr\u003eKey Features \u003cul\u003e\n\u003cli\u003e Speed-controlled refrigeration system with 1400 W cooling capacity (@20°C)\u003c\/li\u003e\n\u003cli\u003e Natural thermofluid R290\u003c\/li\u003e\n\u003cli\u003e Designed for cooling applications up to -30°C - RT\u003c\/li\u003e\n\u003cli\u003e Extended operating temperature range up to 80°C \u003c\/li\u003e\n\u003cli\u003e Excellent temperature stability of about ± 0,1K (@-10°C)\u003c\/li\u003e\n\u003cli\u003e Speed-controlled pump made of PEEK: (0,6 bar; 31l\/min)\u003c\/li\u003e\n\u003cli\u003e Digital level indicator\u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003eAdditional benefits of the control device: \u003cul\u003e\n\u003cli\u003e Operating mode D (confirmation mode)\u003c\/li\u003e\n\u003cli\u003e Signal if set point is reached\u003c\/li\u003e\n\u003cli\u003e Timer\/Counter\u003c\/li\u003e\n\u003cli\u003e Degassing function\u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003eInterfaces: \u003cul\u003e\n\u003cli\u003e Connection socket for external PT 100 temperature sensor (Accessory: PT100.30; Lemo connector)\u003c\/li\u003e\n\u003cli\u003e Connection of magnetic valves possible (Mulit IO)\u003c\/li\u003e\n\u003cli\u003e Alarm contact (Multi IO)\u003c\/li\u003e\n\u003cli\u003e Connector for standby contact input (Multi IO)\u003c\/li\u003e\n\u003cli\u003e RS 232 and USB\u003c\/li\u003e\n\u003c\/ul\u003e \u003cbr\u003e\u003cbr\u003e\n\u003cb\u003eScope of delivery\u003c\/b\u003e\u003cul style=\"padding-top:0px\"\u003e\n\u003cli\u003eRC 5 control\u003c\/li\u003e\n\u003cli\u003ePT 100.30 Temperature sensor\u003c\/li\u003e\n\u003cli\u003eHose olive NW 8 (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eHose olive NW 12 (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eWH10 WiCo Holder\u003c\/li\u003e\n\u003cli\u003eOS 1.0 power supply (for WiCo) \u003c\/li\u003e\n\u003cli\u003eUSB Cable - USB A to Micro-B, 2 m\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 cable Micro A – Micro B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\n\u003ch1\u003eTechnical Data\u003c\/h1\u003e\n\u003ctable border=\"0\" class=\"table-hover table-striped active\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance type\u003c\/td\u003e\n\u003ctd\u003eRecirculating chiller \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling agent\u003c\/td\u003e\n\u003ctd\u003eR290 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling agent quantity\u003c\/td\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling agent pressure max.\u003c\/td\u003e\n\u003ctd\u003e21 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity (@20°C)\u003c\/td\u003e\n\u003ctd\u003e1400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity (@10°C)\u003c\/td\u003e\n\u003ctd\u003e1200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity (@0°C)\u003c\/td\u003e\n\u003ctd\u003e950 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity (@-10°C)\u003c\/td\u003e\n\u003ctd\u003e650 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity (@-20°C)\u003c\/td\u003e\n\u003ctd\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity (@-30°C)\u003c\/td\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature\u003c\/td\u003e\n\u003ctd\u003e-30 - room temp. °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature min.\u003c\/td\u003e\n\u003ctd\u003e-30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature max. (with external heating)\u003c\/td\u003e\n\u003ctd\u003e80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature display\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control\u003c\/td\u003e\n\u003ctd\u003ePID \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature sensor\u003c\/td\u003e\n\u003ctd\u003ePT 100 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking temperature display\u003c\/td\u003e\n\u003ctd\u003eTFT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature stability DIN 12876\u003c\/td\u003e\n\u003ctd\u003e±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection for ext. temperature sensor\u003c\/td\u003e\n\u003ctd\u003ePT 100 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay for operation with ext. sensor\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning function optical \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning function acoustic \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarning function excess temperature \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-level protection\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilling volume\u003c\/td\u003e\n\u003ctd\u003e5.0 - 7.0 l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump type\u003c\/td\u003e\n\u003ctd\u003ePressure- \/ suction pump \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump capacity adjustable \u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump pressure max. (0 liters discharge flow)\u003c\/td\u003e\n\u003ctd\u003e0.61 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure pump (suction side) (0 liter flow)\u003c\/td\u003e\n\u003ctd\u003e0.45 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow rate max. (0 bar back pressure)\u003c\/td\u003e\n\u003ctd\u003e31 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump connection\u003c\/td\u003e\n\u003ctd\u003eM16x1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration option\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical data complies with the standard\u003c\/td\u003e\n\u003ctd\u003eDIN 12876 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ON time\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm output (potential-free contact) max. \u003c\/td\u003e\n\u003ctd\u003e30 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm output (potential-free contact) max. \u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolenoid valve output\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolenoid valve output max.\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby input\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level \u003c\/td\u003e\n\u003ctd\u003e61 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e310 x 546 x 490 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e37.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible ambient temperature\u003c\/td\u003e\n\u003ctd\u003e5 - 32 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible relative humidity\u003c\/td\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class according to DIN EN 60529\u003c\/td\u003e\n\u003ctd\u003eIP 21 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS 232 interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB interface\u003c\/td\u003e\n\u003ctd\u003eyes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100 - 115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e1100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"IKA Works","offers":[{"title":"Default Title","offer_id":43620417011881,"sku":"0020008504","price":8706.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0401\/5452\/9953\/products\/4183000_1_e07a5702-8db3-4174-8cf8-e0038920e52c.jpg?v=1706925019","url":"https:\/\/labproinc.myshopify.com\/products\/ika-works-rc-5-control-0020008504","provider":"Lab Pro Inc","version":"1.0","type":"link"}